Discuss your project
Portable power & charging

Nomad 540

Portable BESS + 180 kW DC Fast Charger

A 540 kWh portable battery energy storage system with an integrated 180 kW dual-port DC fast charger — purpose-built to power and charge electric construction equipment and other on-site loads. Pairs an NCA battery system with two CCS2 outputs in a single transportable cabin.

Enquire about this system
Nomad 540 product image
540 kWh180 kWDual CCS2−20°C to +40°C

HD-SPEC-001 · Construction · Site Equipment · Off-grid Charging

Engineering brief

Built for the application.

Portable

A single transportable cabin houses 540 kWh of NCA storage and a 180 kW CCS2 charging stack — easy to relocate around a site.

Plug-and-Play

Standard CEE 100 A AC input, CCS2 charger output and load-balanced dual-port operation make site setup straightforward.

Smart

Software-driven EMS with AI diagnostics, autonomous fault recovery, fire detection and remote console access.

Mission use cases

Where it works.

Electric Construction Equipment

Charges Volvo compact electric machines and other CCS2-compatible construction equipment with two simultaneous load-balanced outputs.

On-site DC Fast Charging

On construction and industrial sites without grid access — or with constrained grid capacity — for any CCS2-compatible load.

Site Power and Equipment Loads

Powers on-site electrical equipment via the integrated charger / PCS output, with remote monitoring and predictive maintenance.

Technical data

Full specifications.

Battery System
Battery chemistry
NCA · cylindrical cell
Total installed energy
540 kWh
Rated capacity
578.76 Ah
System voltage (min / nom / max)
500 / 660 / 750 V
Continuous charging rate
0.5 C
Continuous discharging rate
1 C
AC Input
AC input voltage
220 V / 380 V AC, 3-phase
Frequency
50 – 60 Hz ± 15 %
Charging time
≈ 7 – 8 h at 90 A, 410 V, 3-phase
Input plug type
CEE plug 100 A
Charger Output
Max power
180 kW
Number of chargers
2
Simultaneous output
Load balance
Efficiency
> 94 %
Charger plug type
CCS2
Environmental
Ambient operating temperature
−20 °C to +40 °C
Max operating altitude
3,000 m
Cooling system type
Compressor (active cooling unit)
Fire suppression
Aerosol · heat / smoke / Li-ion detectors
Mechanical
Dimensions (L×W×H)
3,000 × 2,200 × 2,600 mm
Total weight
5,408.7 kg

Published specifications from Ardenox. Confirm final configuration, performance, certification and suitability for local requirements with our team before project design.

Your next energy project

Let’s put reliable
power in place.

From your first installation to a larger portfolio, talk to our team about sizing, financing and deploying the right system.

Talk to our team